A következő címkéjű bejegyzések mutatása: column orientation. Összes bejegyzés megjelenítése
A következő címkéjű bejegyzések mutatása: column orientation. Összes bejegyzés megjelenítése

2016. november 23., szerda

A pure breed uppervex Hastings



In snow gun diamond dust displays Parry orientation is often strongly emphasized in relation to column orientation. There may be no signs of column orientation at all, except for perhaps a slight tanget arc brightening on top of 22° halo.

Such displays have made observers to ask themselves whether the uppervex Hastings arc – the Hastings arc component that is touching the uppervex Parry arc – could be sometimes be obseved in addition to the usual Wegener, or even without it. So far displays where light source elevation allows separation of uppervex Hastings and Wegener have not resulted in any candidates.

However, in spotlight displays where lamp is at or below the horizon, we have managed to photograph during the last and this winter a several of cases that are suggestive of an uppervex Hastings. And not even suggestive, but outright assertive.

The uppervex Hastings intensifies with lowering light source elevation, only complication is that it then starts to overlap with Wegener and identification must be done on the basis of other halos in the display. If Parry orientation halos are prominent and column orientation halos such as 46° lateral arcs, diffuse arcs and subhelic and Tricker arc are very weak or absent, then we might say that the “Hastgener” in the display is indeed Hastings arc.

As an example of a display that leaves little doubt of its Hastings nature, here is shown a one that Marko Mikkilä observed this year, on the 2nd January in Sievi. The lamp was resting on the ground on a rather level field and is according to Mikkilä about 3 degrees below the camera.

We see no evidence of column orientation – no 46° lateral arcs, no Tricker, no subhelic arc. Instead, in the image there is an overwhelming helic arc and Tape arcs, which both are solely Parry orientation born. Thus the faint “Hastgener” must be an uppervex Hastings arc, rather than Wegener.




Above is a attempt at simulating with HaloPoint. It supports the Parry scenario untarnished by columns, even though the details may not be quite right. Perhaps the most striking mismatch is with the subanthelic arc, which is bright in simulation but seems to be missing from the photo. However, there is a darker area which looks as if shaped by subanthelic arc. This seems to be a real effect, we have seen similar looking dark voids inside anthelic arcs before and in an upcoming post I will be showing a good example of such darkness associated with this halo. Perhaps the more intense parts of subanthelic arc are outside left outside of Mikkilä’s photo, although in that case it should have been possible to make a matching simulation. I actually did find an option which was better in that respect, but other parts got too wrong to take it seriously.

An earlier display in the same location by Mikkilä seems to also contain a pure uppervex Hastings.



2016. október 18., kedd

All rare halos are missing in this spotlight display, but why?



The mystery deepens. In two previous posts we wondered why some displays are great in their column orientation halos even though the crystals have well caved ends. Here we show a case that appeared on November 22, 2015 in Rovaniemi, where crystals seem not much different, yet rare halos requiring basal faces are completely absent. Even the 46° supralateral arc gives just a whiff. Poor crystal orientations can’t explain the absence of rare halos as the tangent arc is quite sharp. Had we known only about this display, we would be quite happy to explain with cavities, but knowing about the other displays, it is quite puzzling.

Marko Mikkilä, Jarmo Moilanen, Marko Riikonen






2016. február 29., hétfő

Wegener or Hastings?



This spotlight display that was photographed in Rovaniemi on the night of 5/6 January rises the question of whether it is Wegener or Hastings arc or both together that is seen here. From the outset, as there is helic arc but no subhelic arc one could argue that it is rather the uppervex Hastings arc.




When comparing with simulations (below) it does not look that obvious anymore. The curvature and extent of the arc looks more akin to Wegener than Hastings (the side view image). And it is possible to simulate Wegener without subhelic arc by using thin plates in column orientation. Indeed, to have best agreement with the images, in all simulations thin plates were used both in Parry and column orientation.
In the image on the left the crystal h/d is 0.1 for all simulations. In the one on the right it is h/d 0.03 for rotations of 0.5 and 5 degrees, for full rotation simulation h/d 0.1 was used. Crystals are triangular, oriented in Parry orientation so that the tip is pointing up.
Well, none of these simulations come out satisfying. The light source elevation for simulations is -5 degrees.
Marko Riikonen / Nicolas Lefaudeux
– added one more image with simulation containing both Wegener and Hastings